[305]: data by Dr.H.Morbelli, Albacete, Spain
C.Wehner MD(Bremervrde, Germany),
AdShop Our Huge Selection Of Alcon Eye Care Products & More Today! [230]: data by Dr.A.Krmer, Lbeck, Germany
Dr.Schmidt MS612 discontinued A=118.6 a0= 0.416 a1=0.167 a2=0.172 pACD=5.54 sf=1.78 A=119.0 A=119.3 585 [6],[7],[18],[42],[70]
Alcon ReSTOR SN6AD2 (India) A=119.1 a0=1.45 a1=0.40 a2=0.10 pACD=5.64 sf=1.89 A=119.2 A=119.5 31 [314]
[251]: data by Dr.T.Hanemoto, Mito, Japan
AMO Sensar AR40E A=118.4 a0= -2.420 a1=0.157 a2=0.288 pACD=5.41 sf=1.63 A=118.7 A=118.8 653 [18],[19],[65],[97],[121],[172]
C.Grenauer-Kloevekorn, Halle, Germany
J Cataract Refract Surg 2017; 43:14131419 Q 2017 ASCRS and ESCRS.
[27]: data by Dr.W.Lange, Prien, Germany
The single-piece acrylic lenses performed well in all regards. [87]: data by Dr.M.-G.Theophil, Eberswalde, Germany
2013 Dec;39(12):1886-92. doi: 10.1016/j.jcrs.2013.06.021. [138]: data by Dr.E.Tahmaz, Erkelenz, Germany
Hanita SEELENS AF A=119.0 a0=1.25 a1=0.40 a2=0.10 pACD=5.42 sf=1.67 A=118.8 A=119.2 27 [136]
INDICATION: The ClareonAspheric Hydrophobic Acrylic IOLs include the Clareon Aspheric and Clareon Aspheric Toric IOLs and are indicated for primary implantation in the capsular bag in the posterior chamber of the eye for the visual correction of aphakia in adult patients in whom a cataractous lens has been removed. [306]: data by Dr.L.Khaitrine, Reims, France
When the mouse button is released, from Save and be link. Posterior capsule opacification and neodymium:YAG rates with 2 single-piece hydrophobic acrylic intraocular lenses: three-year results. [315]: data by Dres. [116]: data by Dr.Henjes, Torgau, Germany
i-Medical 6011C (HP60-PUV) A=118.8 a0=1.45 a1=0.40 a2=0.10 pACD=5.63 sf=1.85 A=119.1 A=119.4 51 [75]
We believe that effective technology can bring big improvement to healthcare management and patient management. The Alcon Monofocal Toric IOL aspheric design delivers a broad refractive landing zone, giving you predictable distance at 20/20 and consistent functional intermediate (20/32 at 66cm) visual acuity. Polytech Polylens S80 A=117.8 a0=0.49 a1=0.40 a2=0.10 pACD=4.68 sf=0.90 A=117.5 A=117.6 155 [22],[25]
Constants for IOLs characterized by '(Japan)'are based on results for Japanese eyes, which tend to be somewhat longer than Caucasian eyes. [266]: data by Dr. A. Hhn, Oldenburg, Germany
[323]: data by Dr. Katrin Hermes, Oranienburg, Germany
[20]: data by C.Pommerencke, MD, Vejle, Denmark
PMC Kaschube, Linares, Winkgen, Ldenscheid, Germany
WEFISinnovid WEFINO 100 A=118.7 a0= 1.39 a1=0.40; a2=0.10 pACD=5.56 sf=1.81 A=119.0 A=119.4 50 [84],[144]
Visiontech Medical Optics Liteflex A=118.2 a0=1.17 a1=0.40 a2=0.10 pACD=5.30 sf=1.55 A=118.6 A=118.9 63 [270]
[346]: data by Dr. Rudolf Sieben, Aachen, Germany
[338]: data by Dr. Ruth Lapid-Gortzak, Driebergen, The Netherlands
[126]: data by S.Suh MD, Westerville, OH, USA
[339]: data by Bonnie J Brooks MD, Brunswick GA, USA
[352]: data by Dr. Dale Pilkinton, Nashville, TN, USA
Bausch&Lomb Akreos FIT A=118.0 a0=0.78 a1=0.40 a2=0.10 pACD=5.02 sf=1.26 A=118.1 A=118.3 71 [24]
[236]: data by Dr.H.v.Wyk, Johannesburg, South Africa
Oshika T, Fujita Y, Inamura M, Miyata K. Mid-term and long-term clinical assessments of a new 1-piece hydrophobic acrylic IOL with hydroxyethylmeth-acrylate. [262]: data by Dr. J.Novak, Pardurbice, Czech Republic
Bausch&Lomb Soflex2 A=118.1 a0= -1.323 a1=0.038 a2=0.249 pACD=5.20 sf=1.44 A=118.4 A=118.7 216 [14],[23]
The manufacturer's published A-constant was almost identical to that obtained in review (118.4 versus 118.38 for the SA30AL and 118.35 for the SA60AT). [232]: data by Dr.H.J.Gross, Margate, NJ, USA
[369]: data by Biotech Vision, India and Moss Vision, UK
[136]: data by Dr.J.Blazek, Pardubice, Czech Republic
ZEISS AT LISA 801 (Acri.LISA 376D) A=117.7 a0=0.82 a1=0.40 a2=0.10 pACD=5.06 sf=1.26 A=118.1 A=118.0 48 [231]
[213]: data by Dr.H.Stckl, Neuburg, Germany
The AcrySof IQ lens offers these advantages over traditional intraocular lens implants: Reduction of spherical aberration. [225]: data by Dr.C.Johansson, Kalmar, Sweden
[204]: data by Y.Kora, Hamamatsu, Japan
Oculentis LS-312Y A=118.0 a0=0.86 a1=0.40 a2=0.10 pACD=5.04 sf=1.25 A=118.1 A=118.3 86 [393]
eyeonics AT-50SE crystalens A=119.0 a0= 0.318 a1=0.139 a2=0.182 pACD=5.62 sf=1.85 A=119.1 A=119.4 224 [115]
[370]: data by Mr. Azfar W. Chohan, Isle of Man
Croma IDEAlens (HEMA25%) A=118.68 a0=1.19 a1=0.40 a2=0.10 pACD=5.38 sf=1.62 A=118.7 A=118.9 49 [203]
Moss Vision Optiflex MO/F-001 A=118.0 a0=1.06 a1=0.40 a2=0.10 pACD=5.26 sf=1.48 A=118.5 A=118.6 48 [369]
Below are lens constants for popular IOLs to be used with the Hill-RBF calculator. [88]: data by Dr.F.Hhn, Ludwigshafen, Germany
[396]: data by Dr. A. Liermann, Neustadt / Weinstrasse, Germany
[117]: data by Dr.M.Theophil, Brandenburg, Germany
[382]: data by Dr. KIM Joon Hyun, Seoul, South Korea
[15]: data by J.Chvojkova, MD, Prague, Czech Republic
Kaschube, Linares, Winkgen, Ldenscheid, Germany
[224]: data by Dr.F.Bauer, Rosenheim, Germany
[83]: data by Jack Singer, MD, USA
3: Safe More. [399]: data by Afidera GmbH, Berlin, Germany
[159]: data by John Merriam, MD, columbia.edu, USA
Polytech Polylens AS64 A=118.4 a0= -1.336 a1=0.272 a2=0.220 pACD=5.26 sf=1.46 A=118.4 A=118.6 261 [220],[287]
In verbal descriptions, IOL optic centration was assessed to be within 0.4 mm of perfect in 75 (95%) of 79 cases. [134]: data by Dr.Chr.Chassain, Montpellier, France
Domilens Nex-Load Preloaded A=119.2 a0=1.73 a1=0.40 a2=0.10 pACD=5.87 sf=2.11 A=119.5 A=120.0 98 [222]
The Open University is incorporated by Royal Charter (RC 000391), an exempt charity in England & Wales and a charity registered in Scotland . [249]: data by Dr.V.I.Apostolov, Amsterdam, The Netherlands
[26]: data by K.Ichikawa, MD, Aichi, Japan
[200]: data by Dr.D.Klaessen, Eichsttt, Germany
[330]: data by Dr. Gilles Lesieur, Albi, France
[111]: data by Dr.A.Schweiker, Pforzheim, Germany
[248]: data by Kazuo Ichikawa MD, Nagoya, Japan
[225]: data by Dr.C.Johansson, Kalmar, Sweden
[169]: data by Dr.Angel Lopez Castro, Madrid, Spain
Hoya UV55SB (Japan)(**) A=117.6 a0=1.38 a1=0.40 a2=0.10 pACD=5.57 sf=1.68 A=118.6 A=118.5 109 [80]
We use cookies to ensure that we give you the best experience on our website. Oculentis L-313 A=118.0 a0= 0.82 a1=0.40 a2=0.10 pACD=5.01 sf=1.26 A=118.1 A=118.4 23 [170]
[383]: data by Dr. KIM Jun Heon, Seoul, South Korea
Alcon ReSTOR SV25T0 A=119.1 a0=1.66 a1=0.40 a2=0.10 pACD=5.82 sf=2.07 A=119.5 A=119.8 70 [147],[367]
[78]: data by Prof.Dr.Th.Neuhann, Mnchen, Germany
Treatment of negative dysphotopsia with supplementary implantation of a sulcus-fixated intraocular lens. Ophtec Artisan 205 aph.retropup. [310]: data by Dr.Trabucchi, Legnano, Italy
[62]: data by Dr.K.Binder, Schramberg, Germany
[133]: data by Keith Kellum, MD, Houma, LA, USA
Biotech Vision Eyecryl Plus 600 A=118.0 a0=0.94 a1=0.40 a2=0.10 pACD=5.19 sf=1.42 A=118.4 A=118.5 51 [369]
Sieber and Fleischer, Halle, Germany
[349]: data by Dr.Dhaval S. Modi, Ahmedabad, India
SIFI Mini 4 Ready A=118.6 a0=1.60 a1=0.40 a2=0.10 pACD=5.63 sf=1.83 A=119.0 A=119.4 21 [150]
[203]: data by Dr.K-B.Seemann, Delmenhorst, Germany
A-constant The constant is a theoretical value that relates the lens power to AL and keratometry, it is not expressed in units and is specific to the design of the IOL and its intended location and orientation within the eye.
Slitlamp photographs showed that 52 (98%) of 53 IOLs were in the same position 9 months after surgery as on the day of surgery. Physiol Slimflex/Yellowflex A=118.5 a0=1.36 a1=0.40 a2=0.10 pACD=5.52 sf=1.74 A=118.9 A=119.3 27 [134]
[150]: data by Dr.G.Savini, Bologna, Italy
[174]: data by Dr.S.Kretschmar, Bautzen, Germany
Tell us something about it and help others to make the right decision, We use UPS, Fedex, USPS and our sellers ship quickly and securely, Customer satisfaction is our top priority, we are not happy until you are happy. [327]: data by Mr. Say Aun Quah and Mrs. C.Gore, Manchester, UK
ZEISS CT 47S (Acri.Lyc 47S) A=117.6 a0=0.95 a1=0.40 a2=0.10 pACD=5.14 sf=1.37 A=118.3 A=118.5 165 [214],[215],[229]
AMO Tecnis ZM900 A=119.0 a0=1.60 a1=0.40 a2=0.10 pACD=5.89 sf=2.21 A=119.8 A=120.5 118 [71],[72],[77],[79]
[158]: data by Dr.Peter Fox, Chichester, UK
[269]: data by Augenzentrum Maus, Kln, Germany
[94]: data by Polytech GmbH, Germany
[54]: data by Dr.A.Gross, Burghausen, Germany
Model Characteristics Chart Model Optic Type Haptic Angle Anterior Asymmetric Biconvex DESCRIPTION The AcrySof IQ UV and blue light filtering acrylic foldable single-piece posterior chamber intraocular lens (IOL) is an optical implant for the replacement of the human crystalline lens in the visual correction of aphakia in adult patients [38]: data by Dr.Michaela Mees, Sulzbach, Germany
HHS Vulnerability Disclosure, Help This page is available in English. ULIB Home
[86]: data by Dr.E.Becker, Oranienburg, Germany
Vol.
For the Clareon Aspheric Toric IOLs, rotation can reduce astigmatic correction; if necessary lens repositioning should occur as early as possible prior to lens encapsulation. [104]: data by Prof.Dr.V.Seiberth, Germany
Optimized IOL Constants for the ZEISS IOLMaster calculated from patient data on file
The site is secure. i-Medical Overview AS natural A=118.8 a0=1.94 a1=0.40 a2=0.10 pACD=6.10 sf=2.33 A=119.8 A=120.2 49 [320]
[135]: data by B.Shingleton, MD, Boston, MA, USA
[64]: data by Dr.U.Weimantel, Frth, Germany
[202]: data by M.Franke, Kirchberg, Germany
In two further optimisations, the formula . [384]: data by Prof. JOO Choun-Ki, Seaoul, South Korea
Polytech Polylens A60 A=118.0 a0=0.85 a1=0.40 a2=0.10 pACD=5.05 sf=1.31 A=118.2 A=118.6 57 [35]
Careers. The https:// ensures that you are connecting to the ACRYSOF Aspheric UV Absorbing ReSTOR +2.5 D Toric IOL, ACRYSOF IQ RESTOR +2.5 D Multifocal Toric IOL, ACRYSOF IQ RESTOR +3.0 D Multifocal Toric IOL, ACRYSOF MultiPiece - Posterior Convex IOL & EXPAND Series IOLs, AIR OPTIX AQUA Multifocal Contact Lenses, AIR OPTIX for Astigmatism Contact Lenses, AIR OPTIX NIGHT & DAY AQUA Contact Lenses, AIR OPTIX plus HydraGlyde Contact Lenses, AIR OPTIX plus HydraGlyde for Astigmatism Contact Lenses, AIR OPTIX plus HydraGlyde Multifocal Contact Lenses, (proparacaine hydrochloride ophthalmic solution, USP) 0.5%, Anterior Chamber Lenses - KELMAN MULTIFLEX III PMMA Single-Piece IOL. [136]: data by Dr.J.Blazek, Pardubice, Czech Republic
[99]: data by IOLtech
Fifty-four percent of the surgeons say they use the Alcon IQ Aspheric IOL for most of their cases, while 31 percent prefer the J&J Vision Tecnis one-piece lens.
Before [246]: data by Dr.Marita Amm, Erlangen, Germany
Secondary surgical interventions include, but are not limited to: lens repositioning, lens replacement, vitreous aspiration or iridectomy for pupillary block, wound leak repair, and retinal detachment repair. Nd:YAG capsulotomy rates after use of the AcrySof acrylic three piece and one piece intraocular lenses.
document.write(part3 + '<\/a>'); VSY Acriva UD 613 A=118.0 a0=0.95 a1=0.40 a2=0.10 pACD=5.19 sf=1.43 A=118.4 A=118.6 49 [254]
[249]: data by Dr.V.I.Apostolov, Amsterdam, The Netherlands
The PubMed wordmark and PubMed logo are registered trademarks of the U.S. Department of Health and Human Services (HHS). [367]: data by Dr. Ralf Schmitt, Saarbrcken, Germany
[387]: data by Dr. BAE Gye Jong, Incheon, South Korea
[256]: data by Prof.Dr.Andrzej Dmitriew, Poznan, Poland
Rayner Superflex 620 H A=118.0 a0=1.20 a1=0.40 a2=0.10 pACD=5.39 sf=1.64 A=118.8 A=119.0 144 [81],[88]
Alcon ReSTOR SV25T0 (India) A=119.1 a0=1.63 a1=0.40 a2=0.10 pACD=5.84 sf=2.05 A=119.3 A=119.6 16 [314]
[172]: data by Prof.Dr.M.Tetz, Berlin, Germany
Schindler, Klaessen, Sendtner, Ingolstadt, Germany
Ralf and Matthias Gerl, Ahaus, Germany
To report the clinical performance characteristics of single-piece acrylic Alcon SA30AL and SA60AT intraocular lenses (IOLs).
Fritz Ruck HA-4-Q A=118.1 a0=1.14 a1=0.40 a2=0.10 pACD=5.29 sf=1.52 A=118.6 A=118.9 88 [102]
[129]: data by J.Chappell MD, Chicago, IL, USA
[389]: data by Dr. C. Dulanto, Inst. Tekia Tek-Lens Mod.411S A=117.8 a0=0.49 a1=0.40 a2=0.10 pACD=4.68 sf=0.90 A=117.5 A=117.6 155 [22],[25]